Model | Cond 50B | Cond 65B | |
Parameters | |||
Rated heating output, min / max | kW | 12/50,4 | 9,4 / 20,3 |
Heating output, min / max | kW | 11,9/49,3 | 8,2 / 18,5 |
Efficiency (60 / 80 °С) | % | 102 | 92 |
NOX class | 6 | 3 | |
Flue gas temperature | °С | 56 | 138 |
G20 gas flow rate, min / max | m3 / s | 0,8 / 5,4 | 0,9 / 2,3 |
Energy efficiency class | А | А | |
Overall features | |||
Net / gross weight | kg | 48,5 / 52 | 29,2 / 30,9 |
Compact size (H × W × D) | mm | 708 × 412 × 488 | 708 × 412 × 260 |
Package size (H × W × D) | mm | 786 × 468 × 565 | 786 × 468 × 312 |
DHW circuit | |||
Hot water temperature, min / max | °С | 35 / 60 | 35 / 60 |
Heating circuit | |||
Operating pressure, min / max | bar | 0,5 / 3 | 0,5 / 3 |
Heating circuit temperature, min / max | °C | 35 / 80 | 35 / 80 |
Electrical features | |||
Voltage / frequency | V / Hz | 230 / 50 | 230 / 50 |
Power consumption, max | W | 128 | 128 |
Protection class | IP42 | IP42 | |
Gas pressure | |||
G20 natural gas (inlet pressure) | mbar | 13 / 20 | 13 / 20 |
G30 / G31 liquified gas (inlet pressure), min / max | mbar | 30 / 37 | 30 / 37 |
Hydraulic Group
- Hydraulic group material: stainless steel
- Heating circuit material: heat exchangers made of stainless steel
- Double heating circuit NTC temperature sensors
- 0,5 bar low water pressure switch
- 6 bar pressure relief valve
- Automatic air bleeding valves
Electrical Circuit
- Safety system compatible with C EN 298
- IPX4D electrical protection
- Weather-integrated outdoor air sensor (can be obtained externally)
- Anti-freeze system
- Overheating protection system
- Flue gas safety system
- Automatic diagnosis function
Gas Circuit
- Flame ionization control
- Automatic control and safety components
- Mixer for accurate mixture of gas and air